TM 10-4130-237-14
4-31.
WATER PUMP REPLACEMENT (CONT)
2
3
4
5
6
7
Place locking key in slot on water pump shaft.
Install center hub on end of water pump shaft in alinement with locking key.
While sliding center hub back on water pump shaft, place faceplate loosely on center hub.
Push water pump drive hub assembly back against water pump. Adjust to provide clearance of at least
0.010 in. (0.25 mm) between assembly and water pump.
Install two socket-head screws in faceplate.
Wrap the threads of the water pump inlet and outlet hose fittings with tape.
4-87