TM 10-4130-237-14
5-16.
EXPANSION VALVE REPLAY (CONT)
5 Remove 16 bottom plate mounting screws. Remove bottom plate*
Remove tube assembly from expansion valve leading from filter drier.
Remove tube assembly from expansion valve leading from evaporator.
8
Remove expansion valve and bulb assembly.
c. Installation
6
7
1
2
3
4
5
Install new expansion valve and bulb assembly.
Install tube assembly at expansion valve leading fkom evaporator.
Install tube assembly at expansion valve leading from filter-drier.
NOTE
If any refrigeration system components have been removed or replaced, in-
stall a new filter-drier before evacuating system (para 5-19).
Leak-test system (para 5-7).
Install bottom plate. Install 16 bottom plate mounting screws.
5-53