5-21. WATER PUMP REPAIR (CONT)
3
4
5
6
7
8
9
Remove impeller from splined shaft.
Remove cam mounting screw. Remove cam.
Tap splined shaft and bearing housing out of pump housing.
Drive shaft seal from pump housing.
Remove rotating shield and stationary slinger.
Remove bearing from pump housing.
Remove bearing shield from pump housing.