TM 10-4130-240-13&P
30 GPH COOLER
REMOTE MODEL
INSTALLATION
1.
This unit is intended for remote installation only. It is
important to insure proper ventilation. Allow a
minimum clearance of 6 inches In front and 6 inches
in the rear of unit.
2.
Water inlet and outlet are 3/8" FPT, located on left
side of unit.
3.
Connecting plumbing lines to be of copper or brass.
Before connecting to cooler, thoroughly flush water
lines to remove all foreign particles. If flushing does
not remove all particles, install a water strainer in the
supply line.
4.
Connect cooler to the building supply line with a
shut-off valve. Install a union connection between the
shut-off valve and the cooler.
5.
Electrical: Make sure power supply is identical in
voltage, hertz, and phase to that specified on cooler
serial plate. Never wire compressor directly to the
power supply.
START-UP
1.
Open supply line valve.
2.
Purge, air from all water lines by operating bubbler
valve of fountain to which cooler is connected.
Steady stream flow assures all air removed.
3.
Rotate fan to assure proper clearance and free fan
action.
4.
Connect to proper electrical power.
TROUBLE SHOOTING & MAINTENANCE
Temperature Control: Factory set for 50° F. water (+5±)
under normal conditions. For colder water, adjust
screw CW on item No. 2 (see diagram.
Ventilation: Cabinet Louvers and condenser fins should
be periodically the above cleaned with brush, air
hose or vacuum cleaner. Excess dirt or poor
ventilation can cause no cold water and compressor
cycling on the compressor overload protector.
Lubrication: Motors are lifetime lubricated.
ITEMIZED PARTS LIST
ITEM
NO.
PART NO.
NAME OF PART
1
32176000
Cover-Insulation Box
2
48000072
Control-Cold
3
37268000
Heat Exchanger
4
33075000
Valve-By Pass
5
37269000
Cabinet
6
33484000
Conditioner
7
43543000
Blade-Fan
8
31713000
Motor-Fan
9
70196-C
Screw
10
19050000
Strainer
11
48000036
Compressor
12
30248C
Overload MRA 7950-118
13
48000069
Bale Strap
14
31663000
Grommet
15
19037000
Clip
16
30440C
Capacitor
17
61401-C
Evaporator Ass'y
18
40107001
Screw
19
31817000
Front Panel (Not Shown)
FOR 220/240V 50 Hz USE:
8
38516000
Motor-Fan
11
37895000
Compressor
12
40405028
Overload
16
30441-C
Capacitor
NOTE: All correspondence pertaining to any of the above
coolers or orders for repair parts MUST include model
number and serial number of cooler name and part
number of replacement part.
2222 CAMDEN COURT OAK BROOK, IL 60521
REV. 5 90741-c