TM 10-4320-345-13
2-16. PREPARATION FOR MOVEMENT - cont.
h.
Disassemble Boost Pumping Stations. Refer to figure 2-40.
WARNING
To prevent contamination of water system and damage to components, keep rocks, dirt, mud,
sand and debris from entering open couplings and hoses during disassembly.
NOTE
Disassembly of one boost pumping station is shown. Disassembly of three remaining boost
pumping stations is similar.
Refer to para 2-11e to remove coupling clamps.
Bypass Line.
(1) Remove coupling clamp (21) and disconnect end of 6-inch x 50-foot discharge hose (20) from
lateral pipe fitting (wye) (10).
(2) Remove coupling clamp (19) and disconnect 6-inch x 50-foot discharge hose (20) from butterfly
valve (18).
(3) Remove coupling clamp (17) and disconnect butterfly valve (18) from lateral pipe fitting (wye)
(16).
Suction Line.
(4) Remove coupling clamp (15) and disconnect lateral pipe fitting (wye) (16) from butterfly valve
(14).
(5) Remove coupling clamp (13) and disconnect butterfly valve (14) from 6-inch x 10-foot discharge
hose (12).
(6) Remove coupling clamp (11) and disconnect 6-inch x 10-foot discharge hose (12) from suction
port on 600 8pm pump.
Discharge Line.
(7) Remove coupling clamp (9) and disconnect lateral pipe fitting (wye) (10) from butterfly valve (8).
(8) Remove coupling clamp (7) and disconnect butterfly valve (8) from 6-inch x 20-foot discharge
hose (6).
(9) Remove coupling clamp (5) and disconnect 6-inch x 20-foot discharge hose (6) from pressure
relief valve (4).
(10) Remove coupling clamp (3) and disconnect pressure relief valve (4) from check valve (2).
2-89