TM 10-4610-242-13
2-15 PREPARATION FOR MOVEMENT- cont.
(4)
Disconnect regulator (5) from 1 inch x 10 foot discharge hose (4).
(5)
Disconnect two 1 inch x 10 foot discharge hoses (3 and 4) from adapter (2).
(6)
Disconnect adapter (1-1/2 inch female x 1 inch male) (2) from 1-1/2 inch x 25 foot discharge hose (1) (from
bag filler connection kit).
(7)
Repeat steps 1 through 6 for remaining hose and nozzle kits.
(8)
Drain and allow components to dry.
(9)
Install caps and plugs on couplings (para 2-10c).
c.
Disassemble Bag Filler Connection Kits. Refer to figure 2-27.
WARNING
To prevent contamination of water system components, keep dirt mud, sand, and debris from entering
open couplings during disassembly. Make sure protective caps and plugs are installed after
components are disassembled.
To prevent injury to personnel, all water pumps must be shutdown and water pressure relieved from
discharge hoses before disconnecting couplings.
(1)
Disconnect 1-1/2 inch x 25 foot discharge hose (17) from 2 inch gate valve (16).
(2)
Disconnect 2 inch gate valve (16) from wye (13).
(3)
Disconnect 1-1/2 inch x 25 foot discharge hose (15) from 2 inch gate valve (14).
(4)
Disconnect 2 inch gate valve (14) from wye (13).
(5)
Disconnect wye (13) from 2 inch x 20 foot discharge hose (12).
(6)
Disconnect 2 inch x 20 foot discharge hose (12) from wye (8).
(7)
Disconnect 1-1/2 inch x 25 foot discharge hose (11) from 2 inch gate valve (10).
(8)
Disconnect 2 inch gate valve (10) from 2 inch x 20 foot discharge hose (9).
(9)
Disconnect 2 inch x 20 foot discharge hose (9) from wye (8).
(10)
Disconnect wye (8) from 2 inch x 20 foot discharge hose (7).
(11)
Disconnect 2 inch x 20 foot discharge hose (7) from adapter (6).
(12)
Disconnect adapter (4 inch female x 2 inch male) (6) from tee (5).
(13)
Disconnect tee (4) from 4 inch x 20 foot discharge hose (3).
2-70