TM5-3820-256-10
NOTES:
1.
Service the filters each time the oil is changed. Remove the filter cover assembly, then remove the two filter
elements. Clean the inside of the reservoir. Install new elements; reinstall the cover assembly.
2.
A sample of the oil from the hydraulic tank shall be sent to an AOAP laboratory for analysis at 300-hour or 6-
month intervals. Refer to TB 43-0210 for sampling requirements.
3.
When AOAP laboratory support is not available, drain and refill the hydraulic tank at 1500 hours or 9 months.
Figure 3-17. Lubrication Instructions for Hydraulic Reservoir (Sheet 2 of 2)
3-41