TM 5-3825-226-24
SHUTOFF HOUSING
INSTALL SHUTOFF HOUSING
Tools Needed
A
1P529
Handle
1
1P460
Plate
1
1.
Put 5S1454 Sealing Compound on the outside
diameter of the seal and install the seal (1) with
tooling (A) in the shutoff housing with the lip
toward the outside. The outer face of the seal
must be .039 in. (1.0 mm) below the surface of
the housing. Remove the extra sealing
compound from the housing and the seal after
installation.
2.
Install shaft (3) in the shutoff housing.
3.
Install lever (5) on shaft (3).
4.
Install shaft (2) in the shutoff housing.
5.
Install lever (4) on shaft (3).
6.
Put cover (6) in position on the shutoff housing
and install the two bolts that hold the cover to
the housing.
7.
Install cover (8) on cover (6).
8.
Install solenoid (7) on the cover.
9.
Install cover (6) on the pump housing.
10.
Install the gasket, flange assembly, gasket and
flange on the cover.
3-64