TM 5-3825-229-14&P
4-24.
LIQUID LEVEL TRANSMITTER (cont)
b.
Installation.
(1)
Install elbows (4) and bushing (3) on plug (5). Elbows must be at 900 and in line with plug.
(2)
Feed wires from indicator switch (2) through bushing, elbows and plug. Install indicator switch (2) in elbow
(4).
(3)
Slide assembled indicator switch (2) into hole in rear of tank. Screw plug into tank. Tighten until outside
elbow (4) is vertical with tank center line.
(4)
Install cable through grip (6) and connect harness wires (7) to indicator switch wires. Install grip (6) in
elbow (4).
(5)
Connect battery cables. Refer to para. 4-22.
Liquid Level Transmitter
4-50