TM 5-3895-370-14&P
Table 3-2. Operator Troubleshooting Procedures - CONT.
Malfunction
Test or inspection
Corrective action
ELECTRICAL SYSTEM (CONT)
2.
GAGES DO NOT OPERATE
Inspect gage panel fuse by removing cap (1) and fuse (2) from receptacle (3).
If fuse (2) is bad, notify unit maintenance to replace fuse.
If fuse (2) is OK, notify unit maintenance of the malfunction.
3.
FLOW RATE INDICATOR (GPM METER) DOES NOT OPERATE
Ensure that Ground Speed switch is turned ON (Table 2-2)
If switch is ON, notify unit maintenance of the malfunction.
4.
TAILLIGHTS DO NOT OPERATE.
Step 1. Ensure light switch is turned ON at tow vehicle.
If switch is turned ON, go to Step 2.
Step 2. Check that intervehicular electrical cable is properly attached from distributor to tow vehicle.
If intervehicular electrical cable is not properly attached, attach properly (para 2-9).
If intervehicular electrical cable is attached properly, notify unit maintenance of the
malfunction.
3-15