TM 5-3895-370-14&P
c.
Spraybar Height (Spray Pattern). To determine the appropriate height of the spraybar from the ground, perform
the following test. This test must be performed when unit is ready to begin spraying, after material has been circulating in
the spraybar.
(1)
Ensure that every second and third spraybar valve (1 and 2) on the center section of spraybar (3) remain
closed by removing hair pins (4) and pins (5).
(2)
Open spraybar (3). Refer to para 2-22.
(3)
Raise or lower spraybar (3) until a uniform coating covers the ground. When a uniform coating is apparent,
this is the appropriate height for the spraybar.
(4)
Close spraybar (3). Refer to para 2-22.
(5)
Install pins (5) and hair pins (4) in spraybar valves (1 and 2).
2-14. ENGINE OPERATING PROCEDURES.
a.
Engine Start-up.
NOTE
Before
starting
engine,
read
Preparation for Operation (para 2-9).
(1)
Ensure pump transmission control lever (1) on
control console (2) is in neutral position.
2-27