TM 5-3895-370-14&P
2-17. CONNECTING DISTRIBUTOR TO SUPPLY TANK.
a.
Connecting System to Supply Tank.
(1)
Start engine (1) (para 2-14) and idle at 1200 RPM.
NOTE
· If longer bituminous hoses are necessary, use 3-inch connectors, from storage
rack, to connect hoses together.
· Refer to para 2-16 for the proper and safe procedure to connect bituminous
hoses.
(2)
Connect hose (3) to outlet port (4) on distributor (5).
(3)
Connect hose (3) to inlet port (6) on supply tank (7).
(4)
Connect hose (8) to inlet port (9) on distributor (5).
(5)
Connect hose (8) to outlet port (10) on supply tank (7).
b.
Disconnecting Distributor from Supply Tank.
NOTE
Refer to para 2-16 for the proper and safe procedure to disconnect bituminous
hoses.
(1)
Disconnect hose (8) from outlet port (10) on supply tank (7).
(2)
Disconnect hose (8) from inlet port (9) on distributor (5).
(3)
Disconnect hose (3) from inlet port (6) on supply tank (7).
(4)
Disconnect hose (3) from outlet port (4) on distributor (5).
2-35