TM 5-4610-228-13
TM 08846A-13/1
5-8. REAGENT HEAD ASSY, HYPOCHLORINATION UNIT/REPAIR (CONT).
LOCATION/ITEM
ACTION
REMARKS
a.
b.
c.
d.
e.
f.
g.
Install diaphragm (3), in back of hypochlorinator, turning
clockwise.
Install washer (9), in top and bottom of liquid head (4).
Install check valve stem (11), in bottom check valve body (5).
Install bottom check valve body (5), in liquid head (4), with check
valve stem (11), pointing down.
Install check valve stem (11), in top of liquid head (4).
Install washer (9), in top and bottom tube nut (6).
Connect discharge hose assy (7), and suction hose assy (12), to
top and bottom valve bodies (5).
5-11