TM 5-5430-248-13&P
FIELD LEVEL MAINTENANCE
500 GALLON WATER DRUM DWDM5CG
TEMPORARY REPAIR OF DRUM BODY, METHOD 2
INITIAL SET-UP:
Tools:
Personnel:
One (77W)
Materials/Parts Required:
CAUTION
Do not tow drum after using Method 1 to repair
leaking drum. Towing drum could further damage
drum.
NOTE
This procedure only applies if the tear in the drum is
3/8 inch length or less.
After temporary repair, the drum can only be used
until empty.
REPAIR
1. Using rotary cutter, use cutter edge to cut a clean edge around the tear. (Figure 1, Item 1).
1