ITEM
INTERVAL
ITEM
TO BE
PROCEDURES
CHECK FOR AND HAVE
REPAIRED OR ADJUSTED
EQUIPMENT
IS NOT READY
NO.
B D A
D W M Q S
A
INSPECTED
AS NECESSARY
AVAILABLE IF
TM 55-1930-209-14&P-17
Table C-1. Preventive Maintenance Checks and Services for Workboat, Lifesaving,
and Firefighting Systems (Continued)
B - Before
D - Daily
Q - Quarterly
D - During
W - Weekly
S - Semiannually
A - After
M - Monthly
A - Annually
6)
Loosen the stator assembly mounting
screws through the holes in the fly-
wheel. To correct timing, rotate the
stator assembly as required (clock-
wise to retard the timing; counter-
clockwise to advance the timing).
7)
Tighten the stator assembly mounting
screws.
8)
Install lower fan pulley, fan belt, and
secure with three hexhead bolts.
9)
Install retractable starter and secure
with three hexhead bolts.
10) Remove the "OUT OF SERVICE" tag.
s.
Check the water seal annually or when
Class III leaks.
the water seal is leaking, as follows:
1)
Shut down the pump and tag "OUT
OF SERVICE."
WARNING
Water seal is spring loaded.
2)
Remove section head and hose
adapter assembly.
3)
Remove and discard gasket.
4)
Remove impeller screw, washer, and
impeller seal.
5)
Screw a 5/8-11 X 2-1/2 in long hex
head bolt into impeller until snug, then
continue screwing in bolt until impeller
comes free.
6)
Remove water seal and inspect for
Seal is worn or
wear and/or defects.
damaged.
7)
If damage is indicated, install new
water seal.
C-39