TM 10-4130-237-14
2-6.
OPERATING PROCEDURE (CONT)
CAUTION
To prevent clogging, do not operate chiller without strainer in WARM IN
hose.
2 Connect three water hoses to water chiller. Place other end of warm in hose in pail of solution. Water
will be discharged from cool recirculate and cool dispense hoses into waste container.
3 Start water chiller. (See paragraph 2-6a.)
CAUTION
To prevent undissolved hypochlorite crystals from entering system, do not usc
water from bottom of pail. Leave about 1/2 gallon (2 liters) of solution in each
pail.
4 With engine running, place START RUN water control in RUN position and circulate both pails of
chlorine solution through water system.
2-24