TM 10-4320-345-13
4-17.
DISCHARGE AND SUCTION HOSE REPAIR - cont.
CAUTION
Ensure gasket is fully seated in gasket seat of coupling/dust cap to prevent leaks in assembled
components.
(14)
Install gasket (8, figure 4-8) in female coupling (2).
(15)
Install gasket (7) in dust cap (6).
(16) Connect split ring (4) to male coupling (5) Install dust cap (6) on coupling.
(17)
Connect split ring (1) to female coupling (2) Install dust plug (3) on coupling.
(18)
Install hose in water system (para 3-4b).
(19)
Startup water system (para 2-13c) and test repaired hose for leaks.
Figure 4-8. Discharge and Suction Hose Assembly.
4-37