4-29. Y-CONNECTOR REPAIR - cont.
(4) Align reducer assembly (4) with y fitting (7) and install coupling clamp (3).
(5) Align reducer assembly (2) with y fitting (7) and install coupling clamp (1).
(6) Install Y-connector in water system (para 3-4).
(7) Startup water system (para 2-13c) and check Y-connector for leaks.
Figure 4-24. Y-Connector Assembly.