Cleaning.
(1) Wash all components with clean water and detergent.
(2) Rinse components in clean water and dry with wiping rag.
(1) Inspect female coupling (12) and male coupling (22) for cracks and corrosion.
(2) Inspect water meter main case (27) for cracks, damage and corrosion.
(3) Inspect meter unit (25) for cracks, damage and corrosion.
Repair. Replace damaged or defective parts. Replace gaskets (14 and 17), flange gaskets (13 and
23), meter gasket (26) and self locking nuts (3, 8 and 18).
Assembly.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
Position gasket (26) on meter main case (27).
Lower meter unit (25) onto gasket (26) and meter main case (27). Make sure arrow on top of the
meter unit is pointing in the same direction as the arrow on the main case.
Install 8 bolts (24).
Position gasket (23) and male coupling (22) on outlet flange of water meter main case (27).
Install eight flat washers (21) , screws (20), flat washers(19) and self locking nuts (18).
NOTE
Ensure gasket is fully seated in groove of cap.
Install gasket (17) in cap (16).
Connect cap (16) to male coupling (22) with ring (15).
Position gasket (13) and female coupling (12) on inlet flange of water meter main case (27).
NOTE
The two screws (5) that attach support bracket (7) to the flange of the water
meter are longer than the other six screws (10) used on the flange.
Install six flat washers (11), 3 1/4-inch long screws (10), flat washers (9) and self locking nuts (8).
Position support bracket (7) on water meter body (27).
Install two flat washers (6), 3 3/4-inch long screws (5), flat washers (4) and self locking nuts (3).
NOTE
Ensure gasket is fully seated in groove of female coupling.
Install gasket (14) in female coupling (12).
Connect plug (2) to female coupling (12) with ring (1).
Installation. Connect water meter to water system (refer to para 2.10 to connect couplings).
Inspection.