TM 10-4610-234-13
5.3
WATER PRESSURE REGULATOR ASSEMBLY REPAIR - continued.
(12)
(13)
(14)
(15)
(16)
(17)
(18)
(19)
Apply anti-seize tape to threads of coupling half (14). Install coupling half (14) on regulator as-
sembly (3).
NOTES
Ensure gasket is fully seated in groove of coupling half.
Ensure coupling half is installed on inlet side of regulator.
When installing coupling half, maintain enough space between
coupling half and regulator so that locking arms will close when
regulator is installed on threaded rods.
Install gasket (5) in coupling half (4).
Apply anti-seize tape to threads of coupling half (4). Install coupling half(4) on regulator assembly
(3).
Install nuts (7 and 9) and washers (6 and 10) on threaded rods (8).
Position four threaded rods (8) and attached parts on board (11).
Install four washers (12) and nuts (13).
Lower regulator assembly (3) onto threaded rods (8).
Install four washers (2) and nuts (1).
5-12