TM 10-4610-237-12
4.14 DISTRIBUTION NOZZLE ASSEMBLY (1 1/2-INCH) REPAIR.
This task consists of:
a.
Disassembly
b.
Cleaning
c.
Inspection
d.
Repair
e.
Assembly
INITIAL SET-UP:
Tools:
Material/Parts:
General Mechanics Tool Kit (Item 1, App. B)
Detergent, General Purpose (Item 1, App. E)
Pipe Wrench (Item 2, App. B)
Wiping Rag (Item 2, App. E}
Equipment Condition:
Tape, Anti-seize (Item 3, App. E)
Distribution nozzle removed (para. 3.4a)
Gasket (Item 1, App. I)
Packing (Item 4, App. I)
Disc (Item 5, App. I)
Disc (Item 6, App. I)
NOTE
Ensure that all parts identified as mandatory replacement parts are discarded and
replaced with new components.
a.
Disassembly. Refer to Figure 42.
(1)
Disconnect S-hook (1) from body (26).
(2)
Remove S-hook (1) from chain and spring (2).
(3)
Remove tube cap (4) and S-hook (3) from chain and spring (2). Disconnect S-hook from tube cap.
(4)
Remove gasket (5) from female coupling (6).
(5)
Remove swivel (7) and female coupling (6) from body (26).
(6)
Unscrew female coupling (6) from swivel (7).
(7)
Drive out groove pin (8) and remove handle (9) from body (26).
4-18