TM 5-3820-256-10Figure 2-47. Well Sounder(2) Chemicals should remain in water 10 to 12 hours before starting pump.(3)After the pump is activated, water may be tested and chemicals added as needed through the draw-downhole in the well seal plate (see figure 2-52).2-38. Installing the Pump.a. AssemblingPump,Motor,andDropHose.(1)Check to see that the drop hose end is cut square. Use a sharp knife or hacksaw to cut the hose. Theninstall the hose coupling into the end of the drop hose (see figure 2-48). If insertion is difficult, cut a 1/2" slitin the end of the hose. This will help you start the coupling into the hose.NOTEDo not use any form of lubrication on the hose or the coupling.(2)Push the hose fully onto the shank of the coupling. The end of the coupling may be tapped lightly on awood surface, if necessary.(3)Cut away about six inches of the cable ridge from the hose. Use a file to smooth the ridge even with theouter hose surface.2-111