TM5-3820-256-10
LUBRICATION INSTRUCTIONS
HYDRAULIC RESERVOIR
NOTE: THESE LUBRICATION ISNTRUCTIONS ARE MANDATORY
TOTAL MAN-HOURS
INTERVAL
MAN-HOURS
INTERVAL
MAN-HOURS
8
0.3
300 or 6M
.2
50 or 30D
.5
KEY
EXPECTED TEMPERATURES
Above
+40 to
0 F to
LUBRICANTS
CAPA-
+32 F
- I0 F
-65 F
CITIES
(Above
(+4 to
(-18 to
0 C)
-23 C)
-54 C)
INTERVAL
OE-HDO
Lubricating
Intervals
(MIL-L-
oil, internal
given are
2104D)
combustion
in hours
engine
of normal
Engine Crank-
3 qt
OE-HDO
OE-HDO
OEA
operation
case
(2.84 L)
30
10
.
OEA
Lubricating
(MIL-L-
oil, internal
46167A)
combustion
engine
Arctic
NOTES:
1.
For operation of equipment in protracted cold temperatures below -10 F (-23 C), remove lubricants prescribed in
the key for temperatures above -10 F (-23 C). Re-lubricate with lubricant specified in the key for temperatures
within 0 F (-18 C) and -65 F (-54 C).
2.
Replace engine oil filter each time oil is changed.
3.
A sample of the oil from the engine crankcase shall be sent to an AOAP laboratory for analysis at 50-hour or 30-
day intervals. Refer to TB 43-0210 for sampling requirements.
4.
When AOAP laboratory support is not available, drain and refill the engine crankcase oil at 300 hours or 6
months.
5.
Remove and inspect the engine air cleaner bowl after 8 hours operation in dusty atmosphere. Wait at least 1
hour after engine is stopped before removing bowl. If there is sludge in the bottom of the bowl, empty oil and
clean the bowl. Refill the bowl with OE/HDO to level mark in bowl. If air cleaner element is heavily
contaminated, remove the element and wash it in clean diesel fuel. Allow all fuel to drip from the element before
reinstalling element.
6.
Check crankcase oil level while engine is stopped and unit is level. Refill to mark on
dipstick.
Figure 3-16. Welder/Generator Lubrication Instructions (Sheet 2 of 2)
3-39