TM5-3820-256-10
Table 3-12. Fuses Blow when Motor Starts (Cont'd.)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6
DEFECTIVE CABLE
to each motor lead.
cable is good, the motor winding
OR MOTOR WIND-
If the needle moves a
is grounded; then contact direct
ING CONT'D.
lot, a ground is indi-
support maintenance.
cated in either the
motor or the drop cable.
7.
SHORTED OR OPEN
Disconnect the motor
Pull the pump and repair or re-
MOTOR WINDING.
leads from the control
place the motor or drop cable.
box; note length and
size of drop cable, then
use an ohmmeter to
check resistance. Low
(or no) resistance will
indicate a shorted motor
winding. High resistance
(no or very little needle
movement) can mean an
open circuit in winding or
broken, but not exposed,
lead cable conductor.
Table 3-13. Pump Runs, But Delivers Little or No Water.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
PUMP IS AIR
Listen for pump running
Start and stop pump at one min-
LOCKED.
but no water noise is
ute intervals. Normal delivery
detected.
may resume
2.
LOW WATER
Water delivery is good
Throttle the pumps delivery
LEVEL IN WELL.
at start up, but delivery
through a restricting valve. Lower
diminishes after a time.
the pump setting if depth of well
Pump capacity is great-
is adequate.
er than well's ability to
produce. Pump may be
set in sand.
3.
PUMP ROTATING
Low water delivery or
Correct pump (motor) rotation
IN WRONG DIREC-
low pressure may indi-
by properly connecting the drop
TION.
cate the pump is oper-
cable wires.
ating in the wrong
direction.
4.
CHECK VALVE
Step 1. If no water is
Valve must be removed.
STUCK OR IMPRO-
being delivered, valve is
PERLY INSTALLED.
installed against the flow.
Step 2. If drop pipe is
Cut off a portion of the drop
screwed into the check
pipe threads.
valve too deep, it may
be jamming the valve in
the closed position.
3-59