TM 5-3825-225-14&P
LUBRICATION CHART
DISTRIBUTOR, WATER, SEMITRAILER MOUNTED,
6000 GALLON, MODEL WD6S
NSN 3825-01-065-6221
Intervals (on-condition or hard time) and related man-hour times are based on normal operation. The man-hour time
specified is the time you need to do all services prescribed for a particular interval. Decrease the intervals if your
lubricants are contaminated, or if you are operating equipment under adverse conditions, including longer-than-usual
operating hours. The intervals may be extended during periods of low activity. If extended, adequate preservation
precautions must be taken.
Dotted leader lines indicate lubrication is required on both sides of the equipment.
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Always wear protective goggles and gloves, and use only
in a well-ventilated area. Avoid contact with skin, eyes, and clothes, and DO NOT breathe vapors. DO NOT use
near open flame or excessive heat. The solvent's flash point is 100 F-130 F (38 C-59 C). If you become dizzy
while using cleaning solvent, Immediately get fresh air and medical help. If solvent contacts eyes, Immediately
wash your eyes and get medical aid.
Clean all fittings and area around lubrication points with dry cleaning solvent (Item 7, Appendix D) or equivalent before
lubricating equipment. After lubrication, wipe off excess oil or grease to prevent accumulation of foreign matter.
The lowest level of maintenance authorized to lubricate a point is indicated in parentheses by use of the following: (C)
Operator/Crew; or (O) Unit Maintenance.
3-2