TM 5-3895-370-14&P
Table 3-2. Operator Troubleshooting Procedures - CONT.
Malfunction
Test or inspection
Corrective action
ENGINE (CONT)
7.
ENGINE EXHAUST SMOKES EXCESSIVELY.
Step 1. Check air restriction indicator for clogged air cleaner filter (para 2-15).
If restriction indicator shows that air cleaner filter is clogged, go to step 2.
If restriction indicator shows that air cleaner filter is OK, notify unit maintenance of engine
malfunction.
Step 2. Visually inspect air cleaner filter (para 3-11).
If air cleaner filter is dirty, clean air cleaner filter (para 3-11). If filter needs to be replaced,
notify unit maintenance to replace filter.
If air cleaner filter is OK, notify unit maintenance of engine malfunction.
8.
ENGINE WILL NOT STOP RUNNING.
Close fuel feed and return valves (para 2-11) and notify unit maintenance of the malfunction.
9.
ENGINE OPERATING TEMPERATURE TOO HIGH.
Step 1. Check engine oil level (para 3-6).
If oil level is below L mark, notify unit maintenance.
If oil level is normal, go to step 2.
Step 2. Check radiator coolant level (para 3-8).
If coolant level is low, add coolant (para 3-8).
If coolant level is normal, notify unit maintenance of the malfunction.
ELECTRICAL SYSTEM
1.
GAGE PANEL OR CONTROL CONSOLE LIGHTS DO NOT OPERATE.
Step 1. Ensure that ignition key switch is turned ON (para 2-14).
If lights do not turn on, go to step 2.
Step 2. Ensure that light switches are turned ON (Tables 2-1 and 2-2).
If lights do not turn on, notify unit maintenance of the malfunction.
3-14