TM 5-3895-370-14&P
Table 1-1. Equipment Data - CONT.
Engine Specifications - Continued:
Journal - minimum ........................................................
2.1245 in. (53.9623 mm)
End Play ......................................................................
0.007 to 0.011 in. (0.178 - 0.279 mm)
Tappet Stem Diameter ........................................................
0.627 to 0.629 in. (15.926 - 15.977 mm)
Lube Pump:
Gerotor Tip Clearance - maximum .................................
0.007 in. (0.178 mm)
Port Plate Clearance - maximum....................................
0.005 in. (0.127 mm)
Body Bore Clearance - maximum...................................
0.015 in. (0.381 mm)
Injection Pump Gear Backlash.............................................
0.003 to 0.013 in. (0.076 - 0.330 mm)
Camshaft Gear Backlash.....................................................
0.003 to 0.013 in. (0.076 - 0.330 mm)
Lube Pump Gear Backlash..................................................
0.003 to 0.013 in. (0.076 - 0.330 mm)
Cooling System:
Capacity.............................................................................
7.4 gal (28 l)
Fuel System:
Fuel Tank Capacity.............................................................
38 gal (143.9 l)
Fuel Injector Pump..............................................................
Mechanical, external
Governor ...........................................................................
Mechanical, internal
Fuel Injectors ......................................................................
Mechanical, pressure activated
Hydraulic System:
Hydraulic Tank Capacity .....................................................
10 gal (37.9 l)
Hydrostatic Pump Capability................................................
17.5 gpm
(66.23 Ipm)
Hydrostatic Motor Capability................................................
10.0 gpm
(37.85 Ipm)
Electrical:
Batteries.............................................................................
Two, 12-volt
Starter ..............................................................................
24-volt (solenoid attached)
Alternator ...........................................................................
24-volt/45 amp
Lighting..............................................................................
24-volt
Circulating System:
Bituminous Pump Capability................................................
350 gpm at 2100 RPM (maximum)
Spraybar ............................................................................
72 valve (maximum)
Flushing Tank:
Capacity.............................................................................
20 gal (75.7 l)
1-10. SAFETY, CARE, AND HANDLING.
a.
Introduction. The following are significant hazards and safety recommendations.
b.
Refueling vehicle. Refueling vehicle is a normal operating condition. Shut off engine and do not smoke when
filling tank. Refer to para 3-7.
c.
Protective Clothing Requirements. Always wear protective clothing to avoid the possibility of burns from flying
asphalt material. Refer to para 2-9b.
d.
Hearing Protection. Always wear hearing protection when operating or working within 16 feet of distributor.
1-10