TM 5-3895-370-14&Pa.Cleaning/lnspection. Use the following cleaning and inspection procedures when replacing any fuel line, fitting, orhose.WARNING·Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protectivegoggles and gloves; use only in a well-ventilated area; avoid contact with skin,eyes, and clothes and do not breathe vapors. Keep away from heat or flame.Never smoke when using solvent; the flash point for type I drycleaning solventis 100°F (38°C) and for type II is 140°F (60°C). Failure to do so may result ininjury or death to personnel. P-D-680 type III is a substitute for types I and II inthis application. The flash point for type III is 200°F (93°C).·If personnel become dizzy while using cleaning solvent, immediately get freshair and medical help. If solvent contacts skin or clothes, flush with cold water.If solvent contacts eyes, immediately flush eyes with water and get immediatemedical attention.·Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa).Use only with effective chip guarding and personal protective equipment(goggles/shield, gloves, etc).(1)Clean banjo screws with drycleaning solvent. Dry with compressed air.(2)Flush fuel tubes with drycleaning solvent. Dry with compressed air.(3)Wipe off fuel tubes with lint-free cloth and inspect tubes for holes, dents, and other damage.(4)Inspect tee, adaptors, and screws for thread bareness.(5)Replace all parts failing inspection.4-93