TM 5-3895-370-14&P
4-142. SPRAYBAR ON/OFF CYLINDER REPLACEMENT (CONT).
WARNING
On/off cylinder is supported by the
clevis pins and is free to fall when
clevis pins are removed. Support
on/off cylinder prior to removing
clevis pins. Failure to comply may
result
in
equipment
damage,
personnel injury, or death.
(3)
Remove two cotter pins (5) and clevis pin (6)
from cylinder (3) and adapter (7). Discard cotter
pins.
(4)
Remove cotter pin (8), and clevis pin (9) from
on/off bar (10) and cylinder (3). Discard cotter
pin.
(5)
Remove cylinder (3) from on/offbar (10).
(6)
If damaged, remove yoke (11), nut (12), and
collar (13) from cylinder (3).
b. Installation.
WARNING
On/off cylinder is supported by the
clevis pins and is free to fall when
clevis pins are removed. Support
on/off cylinder until clevis pins are
installed. Failure to comply may
result
in
equipment
damage,
personnel injury, or death.
(1)
If removed, install collar (13), nut (12), and yoke
(11) on cylinder (3).
4-380