TM 5-3895-370-14&P
(9)
Remove cap (22), spring (23), and poppet (24)
from valve body (11).
(10)
Remove and discard preformed packing (25)
from cap (22).
(11)
Remove and discard preformed packing (26)
from poppet (24).
(12)
Remove two screws (27), flange (28), preformed
packing (29), and gasket (30) from valve body
(11). Discard preformed packing and gasket.
(13)
Remove check valve (31) and spring (32) from
flange (28).
(14)
Remove check valve (33), spring (34), and
spring seat (35) from valve body (11).
(15)
Repeat Steps (12) thru (14) for remaining
reservoir assembly.
b.
Cleaning/Inspection.
WARNING
· Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles
and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes and do not breathe vapors. Keep away from heat or flame. Never smoke
when using solvent; the flash point for type I drycleaning solvent is 100°F (38°C)
and for type II is 140°F (60°C). Failure to do so may result in injury or death to
personnel. P-D-680 type III is a substitute for types I and II in this application.
The flash point for type III is 200°F (93°C).
· If personnel become dizzy while using cleaning solvent, immediately get fresh air
and medical help. If solvent contacts skin or clothes, flush with cold water. If
solvent contacts eyes, immediately flush eyes with water and get immediate
medical attention.
· Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa).
Use only with effective chip guarding and personal protective equipment
(goggles/shield, gloves, etc.).
(1)
Clean all parts with drycleaning solvent and dry with compressed air.
(2)
Inspect parts for cracks, worn threads, and excessive wear.
(3)
Replace all damaged parts.
5-147