TM 5-4320-301-13&PTM 08936A-13&P/12-9. WATER SYSTEMS OPERATION.These procedures describe the operation of the FAWPSS system, in thedischarge mode. In the discharge mode, water is discharged from the storage drum by the FAWPSS system.FAWPSS Operation.(1 )Assure FAWPSS has been properly connected (figure 2-2). Refer to TM 10-8110-202-13&P for detailed water drumsetup procedures.(2)Turn handwheel clockwise to open the elbow coupler valve assy (2) on each water drum (1).(3)Open two 2inch valve assy (4).CAUTIONDo not operate pump unless water is flowing through the system.(4 )Start 125GPM pump and engine assembly( 7). For Model WPSS100 refer to TM 5-2805-257-14. For Model 909591refer to TM 5-4320-309-14.(5)Remove water distribution nozzle from hook on stand assy (13). Pull on spring loaded control handle of waterdispensing nozzle (12) to dispense water.(6)Release spring loaded control handle of water distribution nozzle (12) to stop flow of water.NOTEAlways replace the protective cap on the nozzle to keep foreign matter out of the nozzle.(7)System shutdown procedures are performed in the reverse order of operational procedures.Change 8 2-15