TM 5-4610-228-13
TM 08846A-13/1
1-9. PREPARATION FOR STORAGE OR SHIPMENT
a.
Placement of equipment in administrative storage should be for short
periods of time when a shortage of maintenance effort exists.
Items should
be in mission readiness within 24 hours or within the time factors as determined
by the directing authority.
during the storage period appropriate maintenance
records will be kept.
b.
Before placing equipment in administrative storage, current maintenance
services and equipment serviceable criteria (ESC) evaluations should be completed,
shortcomings and deficiencies should be corrected, and all modification work
orders (MWOs) should be applied.
c .
Storage site selection.
Inside storage is preferred for items selected
for administrative storage.
If inside storage is not available, trucks, vans,
conex containers and other containers may be used.
d.
Marine Corps personnel should refer to MCO 4450.7.
1-10. LOCATION AND DESCRIPTION OF WDS20K SYSTEM COMPONENTS (Figure 1-1).
20,000 GALLON WATER TANK (1). Stores potable water. Assumes pillow shape when filled. Handles on sides
of tank moves and positions the tank when empty. When not in use the tank may be folded or rolled and stored
for shipping.
SINGLE TANK CONNECTION KIT (2). Contains hoses, valves, and couplings needed to connect one water
tank.
PUMP CONNECTION KIT (3). Contains components necessary to connect 125 GPM pump to WDS20K system.
125 GPM PUMP, W/ENGINE (4). Supplies water under pressure to the WDS20K system.
HYPOCHLORINATION UNIT (5). Supplies hypochlorite solution to the water in direct proportion to the flow
rate, purifying the water in the WDS20K system.
HOSE CONNECTOR KIT (6). Contains hose connections for the WDS20K system.
NOZZLE CONNECTION KIT (7). Contains connections for the WDS20K system nozzles.
HOSPITAL CONNECTION KIT (8). Connects the hospital-nozzles to the WDS20K system.
1-11. LOCATION AND DESCRIPTION OF WDS40K SYSTEM COMPONENTS (Figure 1-2).
125 GPM PUMP CONNECTION KIT (1). Contains components necessary to connect 125 GPM pump to
WDS40K system.
125 GPM PUMP (2). Supplies water under pressure to the WDS40K system
DUAL TANK CONNECTION KIT (3). Contains hoses, valves, and couplings needed to connect two water tanks.
20,000 GALLON WATER TANK (4). Stores potable water. Assumes pillow shape when filled. Handles on sides
of tank moves and positions the tank when empty. When not in use, the tank may be folded or rolled and stored
for shipping.
1-4
Change 1