3-16 DRAIN ASSEMBLY AND DRAIN HOSE - CONTINUED
ITEM
ACTION
REMARKS
INSTALLATION - CONTINUED
2. Drain fitting
Align the holes in the drain
The epoxy-polyamide
fitting (6) with the holes in the
primer prevents
compression ring of the tank.
electrolytic corrosion.
Coat the bolts (1) and washers
(2) with a thin film of epoxy-
polyamide primer.
Replace the eight washers (2).
Replace the chain (4) with the
plug (3).
Replace the eight bolts (1).
Tighten the bolts down evenly.
FINGER TIGHT ONLY.
If the bolts are not
tightened in sequence the
drain fitting and the
compression rings will be
distorted causing leaks.