TM 5-3825-226-24
ELECTRIC STARTING MOTOR
REMOVE ELECTRIC STARTING MOTOR
start by:
a) remove crankcase guard
1.
Put identification on the electric wires as to their
location on the motor. Disconnect wires (1), (2),
(3) and (4) from the motor.
2.
Remove the three bolts (6) and lower starting
motor (5) from the machine. The weight of
motor is 60 lb. (27 kg).
DISASSEMBLE DELCO-REMY STARTING MOTOR
(3T8946)
1.
Use a suitable marking tool to scribe a line
across the drive housing (1), lever housing (2),
armature housing (3), and frame assembly (4).
2.
Remove five screws (5), screw (6), drive
housing (1), and gasket (7) from lever housing
(2).
3.
Remove three inspection plugs (8) and gaskets
(9) from armature housing (3).
4.
Remove nut (10), lockwasher (11), washer (12),
and insulator assembly (13) from the terminal
stud.
5.
Remove six capscrews (14).
3-40