2-9.3.1 Discharge (Fill) Hose Interconnection Kit.
a. Remove protective plug and cap on tee assy (19, page 2-29). Attach tee assy(11) to discharge hose assy (13,
page 2-29) for the bottom row of tanks so that the tee assy is connected as shown by the callout number (14,
on page 2-29).
b. Remove protective plug and cap from tee assy (12). Connect tee assy (11) to discharge hose assy (15, page
2-29) for top row of tanks.
c. Connect female end of one of the ten 20-foot discharge hose assys to tee assys (16, page 2-29) which are used
for the top row of tanks. Position the hoses as shown on page 2-29.
d. Connect the female end of the second 20-foot discharge hose to the male end of the hose referenced in step
c. Position hoses as shown on page 2-29.
e. Connect and position remaining eight discharge hoses (15, page 2-29) as accomplished in step d.
f. Connect the male end of discharge hose (14) to tee assy (11), which are used for the bottom row of tanks.
2-34