TM 10-4320-303-13
5.6.5 Hypochlorination Unit Frame Assembly Repair .
This task covers:
5.6.5.1 Repair
INITIAL SETUP
Equipment Conditions
General Safety Instructions
Hypochlorination Unit Frame Assembly
Do not work on equipment that is not secure-
removed, paragraph 4.13.8.
ly stabilized to prevent sliding.
Do not work on equipment without following
standard shop safety precautions.
5.6.5.1 Repair.
WARNING
Do not work on equipment that is not securely stabilized to prevent sliding.
Failure to do so may result in personal injury.
a. Repair of hypochlorination unit frame assembly consists of welding cracked seams and frame
members in accordance with MIL-STD-1261 and TM 9-237.
5-22