TM 10-4320-303-13Table 2-7.Operator Preventive Maintenance Checks and Services for TWDS. (Continued)LocationItemNo.IntervalItem to Check/ServiceProcedureNot FullyMission Capableif:DISTRIBUTIONPOINT17Before2 Inch Gate ValveInspect for damage, leaks,2 inch gateand turns freely. If valvevalve isis leaking, damaged, or notdamaged. Classoperating properly, notifyIII leak. Valvesupervisor.does not rotatefreely.18BeforeElbow ValveInspect for damage, leaks,Elbow valve isand improper operation.damaged or notInspect for damaged oroperatingmissing gasket. If valve isproperly. Classdamaged, not operatingIII leak.properly, or Class III leaksDamaged orare present, notifymissing gasket.supervisor.19BeforeNozzleInspect for damage and leaks.Nozzle isEnsure triggers workdamaged. Classproperly.III leak.Trigger is notproperlyoperating.20BeforeDistributionInspect for damage and leaks.Connection isPoint HoseIf hose is damaged or Classloose. Hose isAssembliesIII leaks are present, notifydamaged. Classsupervisor.III leak.2-20