TM 10-4320-303-13
2.3.3 Grooved-End Pipe Quick Disconnect Coupling Clamp Removal and Installation . Remove and
install grooved-end pipe quick disconnect coupling clamp (Figure 2-13) as follows:
Tools
Used To
Rubber Mallet and Clamping Tool (Items
Install 6 inch and 4 inch grooved-
157 and 3, Appendix C)
end pipe quick disconnect coupling
clamps.
Personnel
Two required
NOTE
This is a general procedure for removal and installation of grooved-end pipe quick
disconnect coupling clamps. Follow this procedure when using a grooved-end pipe
quick disconnect coupling clamp to connect two TWDS components.
2.3.3.1 Removal.
Figure 2-13. Grooved-End Pipe Quick Disconnect Coupling Clamp.
a. Position lower portion of grooved-end pipe quick disconnect coupling clamp tool (Figure 2-13,1) under
cradles (2) on lower side of grooved-end pipe quick disconnect coupling clamp (3).
b. Position top portion of grooved-end pipe quick disconnect coupling clamp tool (1) over cradles (4) on
upper side of grooved-end pipe quick disconnect coupling clamp (3).
c. Pull handle of grooved-end pipe quick disconnect coupling clamp tool (1) over grooved-end pipe quick
disconnect coupling clamp (3) and push pin (5) from grooved-end pipe quick disconnect coupling
clamp (3).
d. Remove grooved-end pipe quick disconnect coupling clamp tool (1) from grooved- end pipe quick
disconnect coupling clamp (3).
2-38