TM 10-4320-345-13
Table 2-1. Operator Preventive Maintenance Checks and Services for Model TWDS20 - cont.
Location
Item
Internal
Item to
Procedure
Not Fully Mission
No.
Check/Service
Capable If:
45
During
20K Collapsible
Perform "DURING" PMCS contained
Fabric Tanks
in the applicable TM
DISTRIBUTION
POINT
46
During
Suction loses
a. Inspect hoses for leaks and loose
Class III leak
or unlocked couplings
b. Inspect for crimped, collapsed or
flattened hose
47
During
125 GPM Pump
Perform "DURING" PMCS contained
in the applicable TM
48
During
Discharge Hoses
Inspect hoses for leaks and loose or
Class III leak.
unlocked couplings
b. Check hoses for kinks. Unkink
hoses
49
During
Hypochlorina-
Perform "DURING" PMCS contained
tion Unit
in the applicable TM
50
During
Gate Valves
Inspect for leaks at valve stem and
Class Ill leak
(2-inch)
coupling
51
During
Distribution
Inspect for leaks at control handle and
Class III leak
Nozzles
couplings
(1-1/2 inch)
52
During
Elbow Valves
Inspect for leaks at valve stem and
Class Ill leak
coupling
53
After
SUCTION HOSES
a. Inspect couplings for damage and
Couplings
(6-inch X 10-feet)
missing gaskets
damaged,
gasket
damaged or
b. Inspect for torn, punctured or
missing, hose
damaged hoses
punctured
or torn
c. Inspect for crimped, collapsed or
flattened hose.
PUMPING
STATIONS
54
After
Pipe Fitting
Inspect fitting for cracks and external
Fitting cracked or
(wye)
damage.
damaged
2-19