TM 10-4320-345-13
Table 2-1. Operator Preventive Maintenance Checks and Services for Model TWDS20 - cont.
Location
Item
Internal
Item to
Procedure
Not Fully Mission
No.
Check/Service
Capable If:
DISTRIBUTION
POINT
72
After
Suction Hoses
a
Inspect couplings for damage and Couplings damaged,
missing gasket
gasket damaged or
b
Inspect for crimped, collapsed or
missing, hose punctured,
flattened hose
kinked or crushed
73
After
125 Gpm Pump
Perform "AFTER" PMCS in
accordance with the applicable TM.
74
After
Discharge Hoses
a
Inspect couplings for damage andCouplings damaged,
missing gasket
gasket damaged or
b
Inspect for missing attaching
missing, hose punctured
bolts, nuts and hardware
or torn
c
Inspect for torn, punctured or
damaged hoses
75
After
Hypochlorina-
Perform "AFTER" PMCS in
tion Unit
accordance with the applicable TM.
76
After
Gate Valves
a
Inspect couplings for damage andCoupling damaged, gasket
(2-inch)
missing gasket
damaged or missing,
b
Inspect for missing attaching
hardware missing
bolts, nuts and hardware.
77
After
Distribution
a
Inspect couplings for damage andCoupling damaged, gasket
Nozzles
missing gasket, caps, or plugs
damaged or missing,
(1-1/2 Inch)
b
Check for missing nozzle tube
hardware missing
caps.
78
After
Elbow Valves
a
Inspect quick disconnect couplings.
Valve body cracked or
for damage and missing gasket,
damaged
caps, or plugs
b
Check for missing plugs.
79
After
Nozzle Stands
Inspect for bent or broken legs and
broken chains
2-22