TM 10-4320-345-13
2-16. PREPARATION FOR MOVEMENT-cont.
(9) Disconnect 2 inch x 20 feet discharge hose (16) from Y-fitting (13).
(10) Disconnect 1 1/2 inch distribution nozzle (15) from 2 inch x 20 feet discharge hose (14).
(11) Disconnect 2 inch x 20 feet discharge hose (14) from Y-fitting (13).
(12) Disconnect Y-fitting (13) from 2 inch x 20 feet discharge hose (12).
(13) Disconnect 2 inch x 20 feet discharge hose (12) from 2 inch gate valve assembly (11).
(14) Disconnect 2 inch gate valve assembly (11) from Y-fitting (10).
(15) Disconnect Y-fitting (10) from 2 inch x 20 feet discharge hose (9).
(16) Disconnect 2 inch x 20 feet discharge hose (9) from adapter (8), if installed If adapter is not
installed, disconnect hose from outlet port of hypochlorination unit (7).
(17) Disconnect end of 2 inch x 10 feet discharge hose (5) from adapter (6), if installed If adapter is not
installed, disconnect hose from inlet port of hypochlorination unit (7).
(18) If installed, disconnect 2 inch female x 1 1/2 male adapter (6) from inlet port of hypochlorination unit
(7). Disconnect 1 1/2 inch female x 2 inch male adapter (8) from outlet port of hypochlorination unit
(7).
(19) Remove hypochlorination unit (7) from distribution point Prepare hypochlorination unit for movement
(refer to the applicable TM).
(20) Disconnect 2 Inch x 10 feet discharge hose (5) from discharge (outlet) port on 125 gpm pump (4).
(21) Disconnect 2 inch x 10 feet suction hose (3) from suction (inlet) port on 125 gpm pump (4).
(22) Remove 125 gpm pump (4) from distribution point Prepare 125 gpm pump (4) for movement (refer
to the applicable TM).
(23) Disconnect 2 inch x 10 feet suction hose (3) from 4 inch female x 2 inchmale adapter (2).
(24) Disconnect 4 inch female x 2 inch male adapter (2) from male discharge elbow (1) on 20K
collapsible fabric tank.
(25) Fold nozzle stand assemblies (25 and 26).
(26) Drain and allow components to dry.
(27) Install caps and plugs on component couplings (para 2-11d).
(28) Roll all hoses and secure with tape.
2-71