TM 10-4610-242-13
2-15. PREPARATION FOR MOVEMENT - cont.
(14) Roll up all discharge hoses and secure with tape.
(15) Prepare 125 gpm pump (6) for movement Refer to the applicable TM.
j.
Disassemble 350 Gpm Pump Connection Kit (Water Source). Refer to figure 2-34.
WARNING
To prevent contamination of water system components, keep dirt mud, sand, and debris from entering
open couplings during disassembly Make sure protective caps and plugs are installed after components
are disassembled
To prevent injury to personnel, all water pumps must be shutdown and water pressure relieved from
discharge hoses before disconnecting couplings
(1)
Disconnect 10 foot discharge hose (3) (part of dual tank connection kit 4) from tee (1).
(2)
Disconnect 10 foot discharge hose (2) (part of dual tank connection kit 5) from tee (1).
(3)
Disconnect water meter (4) from tee (1).
(4)
Disconnect water meter (4) from 20 foot discharge hose (5).
(5)
Disconnect 20 foot discharge hose (5) from male (outlet) coupling on hypochlorination unit (6).
(6) Disconnect 20 foot discharge hose (7) from female (inlet) coupling on hypochlorination unit (6).
(7)
Disconnect tee (8) from 20 foot discharge hose (7).
(8)
Disconnect 20 foot discharge hose (9) from tee (8).
(9)
Disconnect 4-inch gate valve (10) from 20 foot discharge hose (9).
(10)
Disconnect 20 foot discharge hose (11) from 4-inch gate valve (10).
(11)
Disconnect end of 20 foot discharge hose (11) from male (discharge) coupling on 350 gpm pump (12).
(12)
Disconnect 20 foot suction hose (13) from female (suction) coupling on 350 gpm pump (12).
(13)
Disconnect 4-inch gate valve (14) from 20 foot suction hose (13).
2-84