TM 10-4610-242-13
2-10. ASSEMBLY AND PREPARATION FOR USE cont.
o.
Assemble Hose and Nozzle Kits. Refer to figure 2-22.
WARNING
To prevent contamination of drinking water, make sure protective caps and plugs are installed
when components are not in use. Do not remove caps and plugs from components until
couplings are ready to be connected.
NOTE
·
A 2 inch female x 1-1/2 male adapter is supplied with each hose and nozzle kit for connecting
the kits directly to a 2 inch discharge hose. These adapters will not be used in this assembly
procedure. Your operating conditions may require use of the adapters.
·
Three hose and nozzle kits are used in the water system Kit no. 1 is shown, kit no 2 and 3 are
similar.
(1)
Connect adapter (1-1/2 inch female x 1 inch male) (2) to 1-1/2 inch x 25 foot discharge hose (1) (from bag
filter connection kit).
(2)
Connect two 1 inch x 10 foot discharge hoses (3 and 4) to adapter (2).
(3)
Connect regulator (5) to 1 inch x I0 foot discharge hose (4). Make sure regulator is positioned with wooden
base down on ground.
(4)
Connect two 1 inch x 10 foot discharge hoses (6 and 7) regulator (5).
(5)
Connect distribution nozzle (8) to 1 inch x 10 foot discharge hose (7).
(6)
Unfold nozzle stand assembly (9) and attach distribution nozzle (8) to bracket on stand.
(7)
Repeat steps (1) through (6) for kit no. 2 and no. 3.
2-58