TM 10-4610-242-13
2-15. PREPARATION FOR MOVEMENT -cont.
(17)
Disconnect 4 inch x 20 foot discharge hose (1) from tee (8).
(18)
Repeat steps 10 through 16 for hose connection kit no 1.
(19)
Drain and allow components to dry.
(20) Install caps and plugs on component couplings (para 2-10c).
(21) Roll all discharge hoses and secure with tape.
f.
Disassemble 4-Inch Hose Connection Kits. Refer to figure 2-30.
WARNING
To prevent contamination of water system components, keep dirt mud, sand, and debris from entering
open couplings during disassembly. Make sure protective caps and plugs are installed after
components are disassembled.
To prevent injury to personnel, all water pumps must be shutdown and water pressure relieved from
discharge hoses before disconnecting couplings.
NOTE
Two 4-inch hose connection kits are used in the water system Kit. no 1 is shown, kit no 2 is similar
(1) Remove butterfly valve (8) from bracket on stand assembly (9). Fold nozzle stand.
(2) Disconnect butterfly valve (8) from 20 foot discharge hose (7).
(3)
Disconnect 20 foot discharge hose (7) from quick acting valve (6).
(4)
Disconnect quick acting valve (6) from tee (4).
(5)
Disconnect tee (4) from 20 foot discharge hose (3).
(6)
Disconnect two 20 foot discharge hoses (2 and 3).
(7)
Repeat steps I through 6 for other 4-inch hose connection kit.
(8)
Drain and allow components to dry.
(9)
Install caps and plugs on component couplings (para 2-10c).
(10)
Roll all discharge hoses and secure with tape.
2-76