TM 10-4610-242-13
2-15. PREPARATION FOR MOVEMENT - cont.
g.
Disassemble 125 Gpm Pump Connection Kit (Distribution Point). Refer to figure 2-31.
WARNING
To prevent contamination of water system components, keep dirt mud, sand, and debris from entering
open couplings during disassembly. Make sure protective caps and plugs are installed after
components are disassembled.
To prevent injury to personnel, all water pumps must be shutdown and water pressure relieved from
discharge hoses before disconnecting couplings.
(1)
Disconnect end of 20 foot discharge hose (12) from adapter (13).
(2)
Disconnect adapter (4-inch male x 2-inch female) (13) from tee (14) (part of 350 gpm pump connection
kit).
(3)
Disconnect 20 foot discharge hose (12) from 2-inch gate valve (11).
(4)
Disconnect 2-inch gate valve (11) from check valve (10).
(5)
Disconnect check valve (10) from 20 foot discharge hose (9).
(6)
Disconnect 20 foot discharge hose (9) from male (discharge) coupling (8) on 125 gpm pump (6).
(7) Disconnect end of 20 foot suction hose (5) from female (suction) coupling (7) on 125 gpm pump (6).
(8)
Disconnect 20 foot suction hose (5) from 2-inch gate valve (4).
(9)
Disconnect 2-Lnch gate valve (4) from 20 foot suction hose (3).
(10) Disconnect 20 foot suction hose (3) from adapter (2).
(11) Disconnect adapter (4-inch female x 2-inch male) (2) from tee (1) (part of 350 gpm pump connection kit).
(12)
Drain and allow components to dry.
(13)
Install caps and plugs on component couplings (para 2-10c).
(14)
Roll all discharge hoses and secure with tape.
(15) Prepare 125 gpm pump (6) for movement. Refer to the applicable TM.
2-78