(7) Connect cap (16) to male coupling (22) with ring (15).
(8) Position gasket (13) and female coupling (12) on inlet flange of water meter maincase (27).
NOTE
The two screws (5) that attach support bracket (7) to the flange of the water meter are longer
than the other six screws (10) used on the flange.
(9) Install six flat washers (11), 3 1/4-inch long screws (I 0), flat washers (9) and self locking nuts (8).
(10) Position support bracket (7) on water meter body (27).
(11) Install two flat washers (6), 3 3/4-inch long screws (5), flat washers (4) and self locking nuts (3).
NOTE
Ensure gasket is fully seated in groove of female coupling.
(12) Install gasket (14) in female coupling (12).
(13) Connect plug (2) to female coupling (12) with ring (1).
(14) Install water meter assembly in water system (para 3-4a).
(15) Startup water system (para 2-12c) and check water meter assembly for leaks.
4-33.
125 GPM PUMP CONNECTION KIT MAINTENANCE.
The 125 gpm pump connection kit consists of the components listed below. Refer to the following paragraphs for
applicable maintenance procedures.
Procedure
Para.
Discharge Hose Repair .......................................................................................................................
4-14
Gate Valve Assembly (2-Inch) Repair .................................................................................................
4-15
Check Valve Assembly (2-inch) Repair ...............................................................................................
4-34
Change 1