TM 10-4610-243-13
Table 2-1.
Operator Preventive Maintenance Checks and Services for Model WSDS-310 - cont.
Item
No
Interval
Location
Item to
Check/Service
Procedure
Not Fully Mission
Capable If:
20
21
22
23
24
25
Before
Before
Before
Before
350 GPM PUMP
CONNECTION KIT
(DISPENSING
POINT)
Tee Assemblies
Water Meter
Hypochlorination
Unit
Suction and
Discharge Hoses
Gate Valves
(4-inch)
350 GPM Pump
Inspect tee bodies for cracks and
corrosion.
a.
Inspect for cracked or broken
cover or indicator
b.
Inspect meter body of cracks
and external damage.
Perform
"BEFORE"
PMCS
contained Unit in the applicable
TM.
a.
Inspect for cuts, tears and
deep abrasions.
b.
Inspect for cracked and bent or
broken. couplings.
c.
Check
for
and
straighten
kinked hoses.
a.
Inspect for loose, broken, or
missing hand wheel.
Rotate
hand
wheel.
Valve
should turn freely.
b.
Inspect valve body for cracks
and external damage.
c.
Inspect for loose or missing
hardware.
Perform
"BEFORE"
PMCS
contained in the applicable TM.
Tee
bodies
cracked
or.
Damaged
Meter
body
cracked
or
damaged
Meter
indicator
broken.
Hoses cut or torn. Couplings
cracked or broken.
Valve cracked, broken or stuck.
Hardware missing.
2-15