TM 10-4610-243-13
Table 2-1.
Operator Preventive Maintenance Checks and Services for Model WSDS-310 - cont.
Item
No
Interval
Location
Item to
Check/Service
Procedure
Not Fully Mission
Capable If:
42
43
44
45
46
47
48
49
50
Before
Before
Before
During
During
During
During
During
During
Gate Valves
(2-inch)
Check Valve
125 GPM Pump
HOSE NOZZLE
CONNECTION KIT
Distribution
Nozzle
Discharge Hoses
Water Pressure
Regulators
BAG FILLER
CONNECTION KIT
Discharge Hoses
Gate Valves
(2-inch)
Tee and Wye
Assemblies
a.
Inspect for loose, broken, or
missing hand wheel. Rotate
hand wheel. Valve should turn
freely
b.
Inspect valve body for cracks
and external damage.
Inspect valve body for cracks and.
external damage.
Perform
"BEFORE"
PMCS
contained in the applicable TM.
Check
for
leaks
when
control
handle is released
a.
Inspect hoses for leaks and
loose. or unlocked couplings.
b. Check hoses for kinks. Unkink
hoses
Inspect
regulator
body
and
couplings. for leaks.
a.
Inspect hoses for leaks and
loose or unlocked couplings
b.
Check hoses for kinks. Unkink
hoses.
Inspect for leaking valve stems
Inspect tee and wyes for leaking
leaking gaskets.
Valve cracked, broken or stuck.
Valve cracked or broken
Leaks (class Ill)
Class 111 leak.
Class 111 leak
Class III leak
Class III leak.
Class Ill leak.
2-20