TM 10-4610-243-13
2-15. PREPARATION FOR MOVEMENT - cont.
(12)
Drain and allow components to dry.
(13)
Install caps and plugs on component couplings (para. 2-10c).
(14)
Roll up all discharge hoses and secure with tape.
g.
Disassemble 125 Gpm Pump Connection Kit (Distribution Point). Refer to figure 2-31.
WARNING
To prevent contamination of water system components, keep dirt, mud, sand, and
debris from entering open couplings during disassembly. Make sure protective caps
and plugs are installed after components are disassembled.
To prevent injury to personnel, the water pump must be shutdown and water
pressure relieved from discharge hoses before disconnecting couplings.
(1)
Disconnect end of 20 foot discharge hose (12) from adapter (13).
(2)
Disconnect adapter (4-inch male x 2-inch female) (13) from tee (14) (part of 350 gpm pump connection
kit).
(3)
Disconnect 20 foot discharge hose (12) from 2-inch gate valve (11).
(4)
Disconnect 2-inch gate valve (11) from check valve (10).
(5)
Disconnect check valve (10) from 20 foot discharge hose (9).
(6)
Disconnecto20 foot discharge hose (9) from male (discharge) coupling (8) on 125 gpm pump (6).
(7)
Disconnect end of 20 foot suction hose (5) from female (suction) coupling (7) on 125 gpm pump (6).
(8)
Disconnect 20 foot suction hose (5) from 2-inch gate valve (4).
(9)
Disconnect 2-inch gate valve (4) from 20 foot suction hose (3).
(10)
Disconnect 20 foot suction hose (3) from adapter (2).
(11)
Disconnect adapter (4-inch female x 2-inch male) (2) from tee (1) (part of 350 gpm pump connection kit).
(12)
Drain and allow components to dry.
(13)
Install caps and plugs on component couplings (para. 2-10c).
(14)
Roll up all discharge hoses and secure with tape.
(15)
Prepare 125 gpm pump (6) for movement. Refer to applicable TM.
2-78
Change 1