TM 10-4930-220-13&P4-13. Drain Valve Assembly.This task covers:a. Inspection b. Cleaningc. ReplaceINITIAL SETUPToolsTool Kit, General Mechanic’s (Appendix B, Section III, item 2).MaterialsRags, Wiping (Appendix E, Section II, item 3)Cleaning Solvent (Appendix E, Section II, item 1 )Clean parts in a well ventilated area. Avoid inhalation of solvent fumes and pro-longed exposure of skin to cleaning solvent. Wash exposed skin thoroughly. Drycleaning solvent used to clean parts is potentially dangerous to personnel andproperty. Do not use near open flame or excessive heat. Flash point of solventis 100°F. (38°C. to 50°C.). Wear eye protection when blowing solvent from parts.Compressed air used for cleaning purposes should not exceed 30 PSI (2.1 kg/cm).Entry into the tank is prohibited unless the tank has been thoroughly purged,and the atmosphere has been tested for air contaminants and oxygen deficiencyby technically qualified personnel.a.General. The drain valve assembly is used for draining the tank or for removing water accumulation.Figure 4-4. Drain Valve Assembly.4-12Change 1